Leveler delivery candidates failed.- Limiter disabled / Female very soft - Karen Savage: sample peak -0.52 dBFS
- Limiter disabled / Female very soft - Karen Savage: true peak -0.50 dBTP
- Limiter disabled / Female peak-stressed - Annie Coleman Rothenberg: sample peak 0.35 dBFS
- Limiter disabled / Female peak-stressed - Annie Coleman Rothenberg: true peak 0.35 dBTP
- Limiter disabled / Male neutral - John Greenman: sample peak 1.19 dBFS
- Limiter disabled / Male neutral - John Greenman: true peak 1.28 dBTP
- Limiter disabled / Male soft - Stewart Wills: sample peak -0.28 dBFS
- Limiter disabled / Male soft - Stewart Wills: true peak -0.21 dBTP
- Limiter disabled / Male hot - Mark Nelson: sample peak -2.72 dBFS
- Limiter disabled / Male hot - Mark Nelson: true peak -2.71 dBTP
- Limiter disabled / Female soft - Kara Shallenberg: sample peak -1.79 dBFS
- Limiter disabled / Female soft - Kara Shallenberg: true peak -1.67 dBTP
- Limiter disabled / Chapter sequence: sample peak 1.20 dBFS
- Limiter disabled / Chapter sequence: true peak 1.28 dBTP
- Built-in Peak / Female very soft - Karen Savage: true peak -2.70 dBTP
- Built-in Peak / Female peak-stressed - Annie Coleman Rothenberg: true peak -2.35 dBTP
- Built-in Peak / Male neutral - John Greenman: true peak -2.13 dBTP
- Built-in Peak / Male soft - Stewart Wills: true peak -2.90 dBTP
- Built-in Peak / Male hot - Mark Nelson: true peak -2.89 dBTP
- Built-in Peak / Female soft - Kara Shallenberg: true peak -2.89 dBTP
- Built-in Peak / Chapter sequence: true peak -2.13 dBTP
| Mode | Calibration RMS | Applied Delta | Program RMS | Program Sample Peak | Program True Peak |
|---|
| Limiter disabled | -22.64 dBFS | +2.14 dB | -20.50 dBFS | 1.20 dBFS | 1.28 dBFS |
| Built-in Peak | -22.65 dBFS | +2.15 dB | -20.62 dBFS | -3.01 dBFS | -2.13 dBFS |
| Built-in True Peak | -22.66 dBFS | +2.16 dB | -20.63 dBFS | -3.01 dBFS | -3.01 dBFS |